Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Electronics (Basel) ; 12(17)2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37974898

RESUMO

Inertial kinetics and kinematics have substantial influences on human biomechanical function. A new algorithm for Inertial Measurement Unit (IMU)-based motion tracking is presented in this work. The primary aims of this paper are to combine recent developments in improved biosensor technology with mainstream motion-tracking hardware to measure the overall performance of human movement based on joint axis-angle representations of limb rotation. This work describes an alternative approach to representing three-dimensional rotations using a normalized vector around which an identified joint angle defines the overall rotation, rather than a traditional Euler angle approach. Furthermore, IMUs allow for the direct measurement of joint angular velocities, offering the opportunity to increase the accuracy of instantaneous axis of rotation estimations. Although the axis-angle representation requires vector quotient algebra (quaternions) to define rotation, this approach may be preferred for many graphics, vision, and virtual reality software applications. The analytical method was validated with laboratory data gathered from an infant dummy leg's flexion and extension knee movements and applied to a living subject's upper limb movement. The results showed that the novel approach could reasonably handle a simple case and provide a detailed analysis of axis-angle migration. The described algorithm could play a notable role in the biomechanical analysis of human joints and offers a harbinger of IMU-based biosensors that may detect pathological patterns of joint disease and injury.

2.
Front Robot AI ; 10: 1190387, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37213243

RESUMO

Soft pneumatic artificial muscles are increasingly popular in the field of soft robotics due to their light-weight, complex motions, and safe interfacing with humans. In this paper, we present a Vacuum-Powered Artificial Muscle (VPAM) with an adjustable operating length that offers adaptability throughout its use, particularly in settings with variable workspaces. To achieve the adjustable operating length, we designed the VPAM with a modular structure consisting of cells that can be clipped in a collapsed state and unclipped as desired. We then conducted a case study in infant physical therapy to demonstrate the capabilities of our actuator. We developed a dynamic model of the device and a model-informed open-loop control system, and validated their accuracy in a simulated patient setup. Our results showed that the VPAM maintains its performance as it grows. This is crucial in applications such as infant physical therapy where the device must adapt to the growth of the patient during a 6-month treatment regime without actuator replacement. The ability to adjust the length of the VPAM on demand offers a significant advantage over traditional fixed-length actuators, making it a promising solution for soft robotics. This actuator has potential for various applications that can leverage on demand expansion and shrinking, including exoskeletons, wearable devices, medical robots, and exploration robots.

3.
Front Robot AI ; 10: 1267642, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38283800

RESUMO

Inflatable fabric beams (IFBs) integrating pleat folds can generate complex motion by modifying the pleat characteristics (e.g., dimensions, orientations). However, the capability of the IFB to return to the folded configuration relies upon the elasticity of the fabrics, requiring additional pressure inputs or complementary mechanisms. Using soft compliant elements (SCEs) assembled onto pleat folds is an appealing approach to improving the IFB elasticity and providing a range of spatial configurations when pressurized. This study introduces an actuator comprising an IFB with pleat folds and SCEs. By methodologically assembling the SCEs onto the pleat folds, we constrain the IFB unfolding to achieve out-of-plane motion at 5 kPa. Besides, the proposed actuator can generate angular displacement by regulating the input pressure (> 5 kPa). A matrix-based representation and model are proposed to analyze the actuator motion. We experimentally study the actuator's angular displacement by modifying SCE shapes, fold dimensions, and assembly distances of SCEs. Moreover, we analyze the effects of incorporating two SCEs onto a pleat fold. Our results show that the actuator motion can be tuned by integrating SCEs with different stiffness and varying the pleat fold dimensions. In addition, we demonstrate that the integration of two SCEs onto the pleat fold permits the actuator to return to its folded configuration when depressurized. In order to demonstrate the versatility of the proposed actuator, we devise and conduct experiments showcasing the implementation of a planar serial manipulator and a soft gripper with two grasping modalities.

4.
Front Robot AI ; 10: 1289074, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38239276

RESUMO

Soft pneumatic artificial muscles are a well actuation scheme in soft robotics due to its key features for robotic machines being safe, lightweight, and conformable. In this work, we present a versatile vacuum-powered artificial muscle (VPAM) with manually tunable output motion. We developed an artificial muscle that consists of a stack of air chambers that can use replaceable external reinforcements. Different modes of operation are achieved by assembling different reinforcements that constrain the output motion of the actuator during actuation. We designed replaceable external reinforcements to produce single motions such as twisting, bending, shearing and rotary. We then conducted a deformation and lifting force characterization for these motions. We demonstrated sophisticated motions and reusability of the artificial muscle in two soft machines with different modes of locomotion. Our results show that our VPAM is reusable and versatile producing a variety and sophisticated output motions if needed. This key feature specially benefits unpredicted workspaces that require a soft actuator that can be adjusted for other tasks. Our scheme has the potential to offer new strategies for locomotion in machines for underwater or terrestrial operation, and wearable devices with different modes of operation.

5.
Micromachines (Basel) ; 12(10)2021 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-34683295

RESUMO

Malaria affects 228 million people worldwide each year, causing severe disease and worsening the conditions of already vulnerable populations. In this review, we explore how malaria has been detected in the past and how it can be detected in the future. Our primary focus is on finding new directions for low-cost diagnostic methods that unspecialized personnel can apply in situ. Through this review, we show that microfluidic devices can help pre-concentrate samples of blood infected with malaria to facilitate the diagnosis. Importantly, these devices can be made cheaply and be readily deployed in remote locations.

6.
Micromachines (Basel) ; 12(8)2021 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-34442593

RESUMO

The majority of soft pneumatic actuators for rehabilitation exercises have been designed for adult users. Specifically, there is a paucity of soft rehabilitative devices designed for infants with upper and lower limb motor disabilities. We present a low-profile vacuum-powered artificial muscle (LP-VPAM) with dimensions suitable for infants. The actuator produced a maximum force of 26 N at vacuum pressures of -40 kPa. When implemented in an experimental model of an infant leg in an antagonistic-agonist configuration to measure resultant knee flexion, the actuator generated knee flexion angles of 43° and 61° in the prone and side-lying position, respectively.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...